DD 240478/479 319433/444 LOSS OF INTERLOCK.LOSS OF PA AND CONTROL EARTH TRIPPED.
DRIVER RESET EARTH CONTROL .PULLED TIS FLAG IN 77354 LEAD COACH. ECS TO CAULDWELL.
RESET TIS FLAG THEN COMPLETE DOOR STRING TEST CARRIED OUT AND ALL TIS SWITCHES TESTED INDIVIDUALLY AND CAB DOORS CHECKED WITHOUT FAULT.
CARRIED OUT DOOR FUNCTIONAL TEST AND FOUND ONE DOOR AT FAULT ON 444 77376 D DOORS WITH FINGER SEAL RUBBING ON DOOR AS SPLIT.
OTMR D/L ON LEAD END 77354.SAVED TO ANALYSER.
ALSO FOUND 433 77354 PA CONTROL UNIT NOT POWERING UP.
RENEWED BOTH PA CONTROL UNITS AS PART OF CAMPAIGN.
TESTED OK.
SUSPECT PA AT FAULT TRIPPED MCB.
JOB CARD RAISED FOR 319444 DOOR FAULT. UNIT FOR C4 EXAM AT HORNSEY.
319013/426 ME 162 STARTED FOR ATTEMPTED SUICIDE AT HACKBRIDGE
319013 OTMR D/L ON BOTH ENDS FOR COMPARISON CHECKS WITH NEXALA FOR PETER REED SAVED ON ANALYSER R DRIVE
DRIVER RESET EARTH CONTROL .PULLED TIS FLAG IN 77354 LEAD COACH. ECS TO CAULDWELL.
RESET TIS FLAG THEN COMPLETE DOOR STRING TEST CARRIED OUT AND ALL TIS SWITCHES TESTED INDIVIDUALLY AND CAB DOORS CHECKED WITHOUT FAULT.
CARRIED OUT DOOR FUNCTIONAL TEST AND FOUND ONE DOOR AT FAULT ON 444 77376 D DOORS WITH FINGER SEAL RUBBING ON DOOR AS SPLIT.
OTMR D/L ON LEAD END 77354.SAVED TO ANALYSER.
ALSO FOUND 433 77354 PA CONTROL UNIT NOT POWERING UP.
RENEWED BOTH PA CONTROL UNITS AS PART OF CAMPAIGN.
TESTED OK.
SUSPECT PA AT FAULT TRIPPED MCB.
JOB CARD RAISED FOR 319444 DOOR FAULT. UNIT FOR C4 EXAM AT HORNSEY.
319013/426 ME 162 STARTED FOR ATTEMPTED SUICIDE AT HACKBRIDGE
319013 OTMR D/L ON BOTH ENDS FOR COMPARISON CHECKS WITH NEXALA FOR PETER REED SAVED ON ANALYSER R DRIVE