BEARING TEST EQUIPMENT SENSOR CABLE FOUND FAULTY.
SHOWING SHORT CIRCUIT/OPEN CIRCUIT.
SPARE TEST CABLES AT HORNSEY ON LOAN.
TRYING TO GET THEM BACK TODAY.
319454 DD239900 77444 AT BDM (10 MIN TURN ROUND)
A DOORS RUNNING SLOW. MIN WORKS CARRIED OUT.
SPEED ADJUSTED. NOW WITHIN SPEC.
319453 DD239003 71872 REFITTED INTER CONNECTING DOOR AS ADRIFT.
319428 DD239899 MA FAILURE. CARRIED OUT MIN WORKS CHECKS. ALL OK
MAF BLOWN. MA INTERNALS CHECKED .FOUND COVERED IN GREASE AND BRUSHES DOWN TO BRAIDS.
CARRIED OUT FULL CLEAN,REBRUSH AND FITTED NEW MAF.
COMM PROFILE DONE. MA NOW RUNNING.